iBoot
Just point your browser to iBoot's IP address, enter the
Password and you're one click away from power ON, OFF or Reboot. It's that simple.
iBoot is a network attached, IP addressed, web controlled
power switch. Anyone with a web browser can access iBoot
to perform power On, Off or Cycle (timed power shutdown
Reboot, or power up). iBoot is dual password protected and
uses IP filtering for security.
iBoot uses international standard IEC320 power
connections and is auto sensing for worldwide use. Line
cord and Output Cord are included for North America.
iBoot handles circuits up to 12 Amps (10 Amps at
230VAC).
iBoot-DC supports 5-48VDC, 2 Amps and uses simple screw terminals for power in and out.
The unique Auto-Ping feature allows iBoot to monitor any
IP device on the network and take automatic action
whenever the device is down. With Auto-Ping, you can
monitor your broadband connection by pinging an address
across the network. Reboot automatically when service is
not available.
The new Heartbeat Detect feature allows iBoot to monitor
any server or PC running either the free Heartbeat Generator
Program, or heartbeats integrated into your custom software.
Dataprobe can provide developer support to make
integration easy.
Features Benefits
Access from any
Network point
No field trips required for Reboot. Save
time and money by eliminating service
calls and reducing downtime to a
minimum.
Web Control
No special software required. Works with
any forms capable browser. Easy Web
Administration for all configuration.
Dual Password
& IP Filtering for
Security
Deploy iBoot securely throughout your
organization. User and Admin Passwords.
IP Filtering keeps out unwanted visitors.
IP Addressed,
10/100Base-T
Use on any Ethernet IP network. Public or
private. Supports DHCP and alternate
ports for Web Access.
Automatic
Reboot
Operation
Auto-Ping and Heartbeat Detector.
Automatic Operation for crashed devices.
Auto-Ping pings device while heartbeat
listens for periodic message. Complete
control over frequency and timers.
Developer Assistance and software tools
are free.
Direct TCP and
Software Control
Control iBoot directly from your software
application for the highest degree of power
control integration. Simple protocol is freely
available. Use iBoot control program to call
power control from any network
management system.
Built in Hub
Reduce cabling and simplify installation.
One cable from your network closet serves
the iBoot and server, kiosk, etc. Autosensing for uplink/downlink eliminates the
need for expensive crossover cables.
110/220 VAC
Operation
Auto ranging power input. Deploy iBoot
anywhere in the world. iBoot uses IEC320
Connectors and includes line and
extension cords for North America.
Current Capacity
for your needs
12 Amps at 110 VAC, 10 Amps at 220
VAC. 2Amps at 5-48 VDC. Current for
most Servers, Routers, Kiosks, etc.
|